Parker, Directional Control Valve with Inductive Position Control - Series D1VW,
Part #: D1VW020BNJWI5N

The NG06 direct operated directional control valve D1VW with inductive position control provides high functional limits up to 80 l/min in combination with a low, energy saving pressure drop. It is typically used in safety relevant applications.
| Seal Material: | NBR |
| Spool Code: | 020 |
| Solenoid Option: | With manual override |
| Position Control Type: | Start position monitored side B |
| Input Voltage: | 24 V DC |
| Spool Position: | 2 positions, spring offset in position b, operated in position a |
| Port Connection: | NG06 / CETOP 03 |
| Mounting Type: | Sub base, manifold |
| Actuation Type: | Solenoid |
| Function: | 2-way |
| Maximum Operating Pressure: | P, A B: 350 ; T: 210 bar |
| Maximum Flow Rate: | 70 L/min |
| Maximum Operating Temperature: | 60 °C |
| For Fluid Type: | Hydraulic oil according to DIN 51524 |
| Seal Material: | NBR |
| Weight: | 1.8 kg |
| Minimum Operating Temperature: | -20 °C |
| Body Material: | Cast iron |
Parker’s direct operated directional control valve series D1VW with inductive position control in NG06 (CETOP 03 / NFPA D03) features low energy losses due to optimized flow passages. It offers high functional limits up to 80 l/min and a maximum pressure of 350 bar.
This on/off valve is typically used in safety relevant applications. It complies with the machinery directive 2006/42/EG for use as clamping valve according to EN 201:2010. The start or the end position can be monitored. The position control is available for single and double solenoid valves.
Markets:
• Industrial
• Molding
Features/Benefits:
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Wide product offering – many different options – all valves from one single source
• Short delivery time – no warehousing necessary
Applications:
• All types of safety relevant applications
• Injection molding (safety component according to machinery directive 2006/42/EG)
Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by Parker.
The fail-safe position of the directional valve during power failure is the spring offset or center position.